วันจันทร์ที่ 2 มกราคม พ.ศ. 2560

Fire Pump Design Calculate (การคำนวณและการออกแบบหาขนาด ไฟร์ปั้ม)

Fire Pump Design Calculate 
(การคำนวณและการออกแบบหาขนาด ไฟร์ปั้ม)


Download Appilcation

Fire Pump Design Calculate a Software application for calculation and design of the installation of the Fire Pump system and sprinkler system For Fire Protection. By Fire Pump Design Calculate a Software application have 58 Function For use Calcualte and Design For Sprinkler system installation of the Fire Pump system
Fire Pump it is a type of pump that is part of a fire sprinkler system or a fire hose to act entered into the system with water volume and pressure. Sufficient to operate the fire Protection system designed.
The system consists of Fire Pump


Download Manual Fire Pump Design Calculate Appilcation Link
https://drive.google.com/file/d/0BxaWWGlfYY6NeXk0ejZFLWY0RDg/view?usp=sharing
The fire pump system consists of the following key.
1. Keeping pressure pump (Jockey Pump).
2. Fire pump (pump power).
3. Controlled pumps maintain pressure (Jockey Pump Controller).
4. Controlled pump fire (fire pump Controller).
5. Pressure relief valve
The work of the fire pump system based on water demand within the fire hose engineer will determine the level of pressure on the states to start and stop the pump system failure. firefighters are usually located on the third level in a pump used to power a fire engine and a four-level in the event a fire pump that uses an electric motor to power the sources. "Setting up the pressure Switch fire pump and Jockey Pump ".
Fire Pump Design Calculate a Software application have 58 Function
FUNCTION APPLICATION FIRE PUMP CALCULATE
Function Method For Design
1. Types of Stationary pump
2. Jockey Pump Installation Diagram
3. Horizontal Split-Case Fire Pump Installation
4. Vertical Shaft Turbine-Type Pump Installation
5. Symblo
6. Total Head of Vertical turbine-type Fire pump
7. Total Head of All Types of Stationary-Type Fire Pump
8. Right And Wrong Pump Suction
9. Contact
Function Fire Pump Size Table
1. Fire Pump Table
2. Summery Of Centriugal Fire Pump Data
3. Flow Rate Fluid In Pipe
4. Head Loss Of Fluid Valve &Fitting
5. Flow Pump PIPE
6. Water Supply Calculate
7. Fire Pump Calculate
8. Jockey Pump Calculate
9. Npsh
Function Fire Pump Calculate
1. Fire Pump Calculate Sprinkler Design Area Hydraulic Calculation
2. Fire Pump Calculate Flow Rate Sprinkler Nozzle Hydraulic Calculation
Function Sprinkler Calculate
1. Area Sprinkler
2. Number Sprinkler
3. Flow Sprinkler (Nozzle)
4. Calculate pressure & Flow
5. Frictional Loss Hazen-William Equation (SI)
6. Frictional Loss Hazen-William Equation (US)
7. Fire Pump Calculate Sprinkler
8. Water Supply Calculate
9. Hose Stream Allownce
10. Table For Design
Function Table For Design
1. K-Factor Sprinkler
2. C Value
3. Hose Stream Water
4. K-Factor Valve & Fittings
5. Actual Pipe Diameters
6. Eqiualent Lengths
7. Head Loss of Fluid Valve & Fitting
8. Table Sprinkler Pipe
9. Light Hazard Pipe
10. Ordinary Hazard Pipe
11. Extra Hazard Pipe
Function Graph For Design
1. Moody Diagram Graph
2. Density/Area Curues
3. Alarm Check Valve
4. Deluge Size Design
5. Preaction
6. Velocity Pressure
7. Pump Charctrietics
8. Hydraulic Graph
9. Table
FUNCTION APPLICATION FIRE PUMP CALCULATE& DESIGN



















































































































































ไม่มีความคิดเห็น:

แสดงความคิดเห็น